Files with extensions .rec and .hyp contain original recordings and their hypnograms, respectively, in European Data Format. EDF is specified in
B Kemp, A Värri, AC Rosa, KD Nielsen, J Gade. A simple format for exchange of digitized polygraphic recordings. Electroencephalography and Clinical Neurophysiology 82:391-393 (1992).
More about EDF is on www.edfplus.info. Each EDF file has a header specifying patient, recording and signals including their calibration. Converters to (and from) WFDB native format are included in the WFDB Software Package (see edf2mit(1) in the WFDB Applications Guide). Applications using WFDB library version 10.4.5 or later can read EDF files directly with no conversion required.
The recordings were obtained from Caucasian males and females (21–35 years old) without any medication; they contain horizontal EOG, FpzCz and PzOz EEG, each sampled at 100 Hz. The sc* recordings also contain the submental-EMG envelope, oro-nasal airflow, rectal body temperature and an event marker, all sampled at 1 Hz. The st* recordings contain submental EMG sampled at 100 Hz and an event marker sampled at 1 Hz.
The sc*.rec recordings contain the envelope of the EMG signal, at a 1Hz sampling frequency. The dimension of this envelope signal, "uV-mrs", means "microvolt mean-root-squared", in which 'mrs' is related to, but not synonymous with, the well-known abbreviation 'rms' (root-mean-square). In both rms and mrs, the letters, r, m, and s mean 'root', 'mean', and 'square', respectively. The order of these components differs between rms and mrs, however, making them essentially different variables. In this case, the electrical EMG signal is expressed in microvolts (uV), then rectified (root-squared: rs) and then smoothed (mean: m) over the 1-second time-intervals between two successive samples. So it is the mean (m) of the root-squared (rs) signal: mrs.
The st*.rec recordings came from body-worn bio-signal amplifiers that transmitted those signals digitally to a PC. All transmitters had the same FM radio frequency. So, when two patients were recorded next to each other the FM receivers might mix up those patients. That risk was very small due to the location of transmitter and receiver, but in order to be sure each transmitter had a different baseline of the ID+Sync+Error signal. For instance the st7132j0.rec and st7052j0.rec recordings were made by transmitters numbers 1 and 2, respectively, hence the baseline of the signal is 1 and 2, respectively in those two recordings. The transmitter also had a marker (M) button: pressing the button added 32 to the 'ID+Sync+Error' signal. The system also continuously monitored the quality of the received (digital) signal: any error subtracted 32 from the signal. So, the dimension "ID+M-E" indicates that the baseline of the signal identifies (ID) the transmitter, shows the marker button as a positive deflection (+M) and any error in the telemetry link as a negative deflection (-E). Nice examples are in all ST recordings because the telemetry link in this project was optical and it was disconnected between the hook-up in the afternoon and the start of the trial late in the evening. At the start (at 00:31:17 in st7132j0.rec and 23:23:15hr in st7052j0.rec) the ID+Sync+Error signal switches from negative (error: no connection) to 1 or 2 (ID of the transmitter), and a few seconds later the patient or nurse pressed the marker button which shows as a short (1 second) positive peak. In this project the baseline level proves that in the evening each patient was reconnected to the same file that he was hooked-up on in the afternoon. This is particularly important because the afternoon session included the creation of the patient-ID in the EDF header.
Hypnograms are manually scored according to Rechtschaffen & Kales based on Fpz-Cz / Pz-Oz EEG instead of C4-A1 / C3-A2 EEG: see
B van Sweden, B Kemp, HAC Kamphuisen, EA van der Velde. Alternative electrode placement in (automatic) sleep scoring (Fpz-Cz / Pz-Oz versus C4-A1 / C3-A2). Sleep 13(3):279-283 (1990).
The sleep stages W, 1, 2, 3, 4, R, M and 'unscored' are coded in the file as binaries 0, 1, 2, 3, 4, 5, 6 and 9 according to Q16.3 of the EDF-FAQ.
The 4 sc* recordings were obtained in 1989 from ambulatory healthy volunteers during 24 hours in their normal daily life, using a modified cassette tape recorder. Subjects, recordings and hypnogram scoring are described in
MS Mourtazaev, B Kemp, AH Zwinderman, HAC Kamphuisen. Age and gender affect different characteristics of slow waves in the sleep EEG. Sleep 18(7):557-564 (1995).
The 4 st* recordings were obtained in 1994 from subjects who had mild difficulty falling asleep but were otherwise healthy, during a night in the hospital, using a miniature telemetry system with very good signal quality. Subjects and recordings are more extensively described in the 2000 IEEE-BME paper cited above.
B Kemp, AH Zwinderman, B Tuk, HAC Kamphuisen, JJL Oberyé. Analysis of a sleep-dependent neuronal feedback loop: the slow-wave microcontinuity of the EEG. IEEE-BME 47(9):1185-1194 (2000) [PDF].
Contributors
Bob Kemp, Sleep Centre, MCH-Westeinde Hospital, Den Haag, The Netherlands
When using this resource, please cite the original publication:
Please include the standard citation for PhysioNet: (show more options)
Goldberger, A., Amaral, L., Glass, L., Hausdorff,
J., Ivanov, P. C., Mark, R., ... & Stanley, H. E. (2000).
PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research
resource for complex physiologic signals. Circulation [Online]. 101
(23), pp. e215–e220.
帕依提提提温馨提示
该数据集正在整理中,为您准备了其他渠道,请您使用
- 分享你的想法
全部内容
数据使用声明:
- 1、该数据来自于互联网数据采集或服务商的提供,本平台为用户提供数据集的展示与浏览。
- 2、本平台仅作为数据集的基本信息展示、包括但不限于图像、文本、视频、音频等文件类型。
- 3、数据集基本信息来自数据原地址或数据提供方提供的信息,如数据集描述中有描述差异,请以数据原地址或服务商原地址为准。
- 1、本站中的所有数据集的版权都归属于原数据发布者或数据提供方所有。
- 1、如您需要转载本站数据,请保留原数据地址及相关版权声明。
- 1、如本站中的部分数据涉及侵权展示,请及时联系本站,我们会安排进行数据下线。